Application of Vertical Electrical Sounding (VES) for the Determination of Water-Bearing Zone in Karaworo, Lokoja Kogi State, Nigeria

Abdulbariu Ibrahim *

Department of Geology, Federal University, Lokoja, Kogi State, Nigeria.

Aroke Lateefah Omeneke

Department of Geology, Federal University, Lokoja, Kogi State, Nigeria.

Mu’awiya Baba Aminu

Department of Geology, Federal University, Lokoja, Kogi State, Nigeria.

Pam Dajack Dung

Department of Geology, University of Jos, Plateau State, Nigeria.

Sadiq Mohammed Salisu

Abubakar Tafawa Balewa University, Bauchi, Bauchi State, Nigeria.

Ajogwu Cordelia Odinaka

Department of Geology, Federal University, Lokoja, Kogi State, Nigeria.

Bertha Onyenachi Akagbue

Department of Environmental, Health and Safety, Marshall University, Huntington, West Virginia, USA.

Ibrahim Olanrewaju Ibrahim

Hydrology and Design Units, Lower Niger River Basin Development Authority, Ilorin, Kwara State, Nigeria.

Ayinla Habeeb Ayoola

Department of Geology, Federal University, Lokoja, Kogi State, Nigeria.

*Author to whom correspondence should be addressed.


Abstract

The importance of water in our various communities and the difficulties faced so far to get good and clean water for both domestic consumption and industrial purposes can never be overemphasized. For these purposes to be accomplished, it is necessary to survey the area of study to know more about the geology of the area, which is characterized by the Lokoja Formation, Patti Formation, and Agbaja Ironstone and the possible reasons why there is a lack of water in the area. The geoelectric survey was conducted at Karaworo with the objective of determining the sedimentary formation's geoelectrical features and analyzing the potential of the groundwater in the study area. The most frequently used type of array for Vertical Electrical Sounding (VES) is the Schlumberger array, which needs a lot of space at both ends to yield deeper subsurface information. The Schlumberger configuration was used for data acquisition. About fifteen (15) VES points were acquired at different locations within the study area. For the different VES positions, the maximum AB/2 is within 100m to 180m. Partial curve matching was used to determine the layer parameters as part of the quantitative interpretation of the VES curves. The IP2WIN software was used in the final data analysis. The depth sounding interpretation revealed subsurface layers which comprises of topsoil/clay with a resistivity range between 1.42 ohm-m to 81.0ohm-m and a thickness of 0.253 m to 70.4 m, lateritic clay with a resistivity range between 01.06ohm-m to 1730 ohm-m and a thickness of 0.236 m to 19.2 m, siltstone with resistivity range between 0.423 ohm-m to 5069 ohm-m and a thickness of 4.09 m to 28 m and sandstone with resistivity range between 0.664 ohm-m to 137 ohm-m with the thickness at infinity. Sandstone constituted the aquiferous zone. In conclusion, different types of curves which include HA-type, H-type, KH-type, QH-type and HAK-type characterize the area and hence it is suggested that boreholes be placed in low resistivity zones and considerable depth and thickness as revealed in VES 4 and VES 8 but those with low resistivity without considerable depth, for example, VES 2, VES 5, VES 6, VES 7, etc. can be developed into a hand dug well.

Keywords: Resistivity, water, sandstone, data acquisition, aquiferous, borehole


How to Cite

Ibrahim, Abdulbariu, Aroke Lateefah Omeneke, Mu’awiya Baba Aminu, Pam Dajack Dung, Sadiq Mohammed Salisu, Ajogwu Cordelia Odinaka, Bertha Onyenachi Akagbue, Ibrahim Olanrewaju Ibrahim, and Ayinla Habeeb Ayoola. 2023. “Application of Vertical Electrical Sounding (VES) for the Determination of Water-Bearing Zone in Karaworo, Lokoja Kogi State, Nigeria”. Journal of Geography, Environment and Earth Science International 27 (11):47-73. https://doi.org/10.9734/jgeesi/2023/v27i11726.

Downloads

Download data is not yet available.